UV-C air disinfection · Made in EU

Lightagainstgerms.

UV-C light disinfects the room air. No filters, no chemicals, no ozone. Around the clock, while people are in the room.

CLAIR PRO, white column on castors with blue UV indicators

Wherever people meet, they share the air.

Six places where CLAIR works every day.

CLAIR PRO at the reception of a medical practice

Medical practice and waiting room

Sick and healthy people often sit in the same room for a long time. In winter, constant airing is hardly possible.

The CLAIR PRO disinfects the air during consultation hours. It stands on castors and runs from 34 dB.

Recommended: CLAIR PRO

Care homes and assisted living

Everyone meets in the common room, many with weakened immune systems.

CLAIR runs around the clock, without chemicals and without ozone. The ECO on its stand fits into any corner.

Recommended: CLAIR ECO

Schools and nurseries

20 to 30 children share one room. Constant airing brings cold and draughts in winter.

The CLAIR PRO runs during lessons and rolls on to the next classroom.

Recommended: CLAIR PRO

Offices and meetings

Changing groups in the same room, colds go round.

The CLAIR ECO disinfects the air during and between meetings. Plug in, switch on.

Recommended: CLAIR ECO

Open-plan office

Many workstations, shared air and hardly any floor space.

The CLAIR AIR hangs from the ceiling and takes up no space. It is controlled by app.

Recommended: CLAIR AIR

Restaurants and hotels

Guests and staff share the same room air all evening.

The CLAIR PRO stands discreetly to the side and keeps working at full capacity.

Recommended: CLAIR PRO
The basics

What is UV-C?

UV-C is the most energetic part of ultraviolet light. The sun emits it, but the ozone layer keeps almost all of it away from the earth. CLAIR produces it with OSRAM lamps at 254 nm, safely enclosed inside the unit.

UV-C100–280 nm
UV-B
UV-A
Visible light400–780 nm
254 nmCLAIR

Wavelength in nanometres. The shorter the wave, the more energy the light carries.

  1. 01

    Light hits the germ

    Inside the chamber, UV-C light penetrates viruses, bacteria and fungal spores carried past by the air.

  2. 02

    The DNA absorbs it

    Genetic material absorbs light around 254 nm particularly strongly. This destroys its structure.

  3. 03

    No reproduction

    The germ is inactivated and can no longer reproduce. Pathogens cannot develop resistance to this effect.

Proven for decades in
  • Drinking water
  • Food
  • Air conditioning
  • Medical practices
  • Hospitals

What happens inside CLAIR.

  1. 01

    Intake

    Four fans at the top of the unit draw room air in through the honeycomb grille at the bottom. PRO and AIR are rated at 600 m³ per hour, and the fan speed is adjustable.

  2. 02

    Light trap

    The air flows through zigzag louvres. Air passes through, UV light does not get out. The lamps are never visible from outside.

  3. 03

    Irradiation

    In the closed chamber, five OSRAM UV-C lamps irradiate the air at 254 nm. The radiation hits the DNA of viruses, germs and bacteria.

  4. 04

    Outflow

    Through the second light trap and the fans, the air leaves the unit at the top and returns to the room.

No filters.No ozone.No chemicals.

Just light. Nothing clogs, nothing needs to be reordered, nothing gets into the room air.

  • 01

    254 nm

    UV-C radiation, strongly disinfecting.

  • 02

    up to 99 %

    of viruses, germs and bacteria neutralised.

  • 03

    Works instantly

    Its effectiveness is scientifically proven.

  • 04

    No resistance

    Pathogens cannot develop resistance to UV-C.

  • 05

    Eco-friendly

    Disinfection without chemicals, ozone-free.

  • 06

    People in the room

    Runs while people are in the room. The light stays inside the unit.

  • 07

    24/7

    Built for continuous operation around the clock.

  • 08

    Plug & Play

    Plug in, switch on, done.

  • 09

    High UV-C dose

    Highly efficient OSRAM lamps.

  • 10

    Low maintenance

    No filter, one lamp change a year.

  • 11

    Preventive

    Lowers the germ load continuously, not only when it is too late.

  • 12

    CE · Made in EU

    Manufactured to DIN EN ISO 9001, RoHS compliant.

  • Constant air disinfection
  • Better air hygiene
  • Fewer viruses and germs
  • Effective hygiene management
  • Lower risk of infection
  • Exemplary workplaces
  • Fewer sick days
  • Safety for guests and customers
  • Safety for patients and staff
  • Safety for you and your family

Against viruses, bacteria and fungi.

UV-C light at 254 nm destroys the genetic material of microorganisms. All bacteria and viruses tested so far respond to it. How much light is needed depends on the pathogen.

99.4%

fewer active viruses after a single pass through the unit (model virus MS2, 2.2 log steps, flow-optimised test set-up)

>85%

fewer germs (fungi and bacteria) in the room air after one hour of operation, test room 36.5 m³

Measured on CLAIR by an independent test laboratory in Germany, 2022.

How much UV-C a pathogen needs

Dose for 99.9 % inactivation in mJ/cm². The further left, the easier it is to render a pathogen harmless with UV-C.

  • Shigella paradysenteriae5,2
  • Staphylococcus albus5,4
  • Staphylococcus viridans6,0
  • Staphylococcus hemolyticus6,6
  • Serratia marcescens7,2
  • Staphylococcus aureus7,8
  • Proteus vulgaris7,8
  • Escherichia coli9,0
  • Corynebacterium diphtheriae10,0
  • Bacillus anthracis13,7
  • Pseudomonas aeruginosa16,5
  • Salmonella typhimurium24,0
  • Saccharomyces cerevisiae (yeast)18,0
  • Penicillium roqueforti39,0
  • Aspergillus flavus180,0
  • Aspergillus niger396,0

40 pathogens in the series, of which 25 bacteria, 5 yeasts, 10 moulds. Selection above. Source: Heraeus Noblelight, 2019. Literature values on UV-C sensitivity, not measured on the unit.

Three models. One principle.

Same technology, three designs. What matters is the size of the room and where the unit should stand or hang.

CLAIR ECO

CLAIR ECO

Column on a stand with castors

For single offices, treatment and meeting rooms, care rooms.

Airflow
300 m³/h, 2 speeds
UV-C lamps
3 × 60 W OSRAM
Noise level
34–40 dB
Power consumption
180 W · 0.18 kWh/h
CLAIR PRO

CLAIR PRO

Column on castors

For waiting rooms, classrooms, common rooms and restaurants.

Airflow
600 m³/h, 3 speeds
UV-C lamps
5 × 60 W OSRAM
Noise level
34–44 dB
Power consumption
300 W · 0.30 kWh/h
CLAIR AIR

CLAIR AIR

Ceiling or wall unit

For open-plan offices and rooms with no floor space.

Airflow
600 m³/h, 3 speeds
UV-C lamps
6 × 60 W OSRAM
Noise level
34–44 dB
Power consumption
360 W · 0.36 kWh/h

All data compared

ECOPROAIR
DesignColumn on a stand with castorsColumn on castorsCeiling or wall, on cables
UV-C lamps3 × 60 W OSRAM5 × 60 W OSRAM6 × 60 W OSRAM
UV-C output57 W95 W114 W
Airflow300 m³/h, 2 speeds600 m³/h, 3 speeds600 m³/h, 3 speeds
Fans244
Noise level34–40 dB34–44 dB34–44 dB
Dimensions105 × 30 × 22 cm130 × 33 × 33 cm100 × 55 × 25 cm
Weight20 kg, stand 15 kg30 kg, base plate 9 kg35 kg
ControlsIlluminated ring button, 2 speedsApp ClairPro (Bluetooth)App ClairPro (Bluetooth)
Power consumption (rated)180 W300 W360 W
Consumption per hour0.18 kWh0.30 kWh0.36 kWh
MaintenanceLamp change once a year in continuous operation, clean twice a year, no filter

All models: 254 nm, ozone-free, lamp life 9,000 h, 220–240 V, powder-coated sheet steel housing, Made in EU.

Which model suits your room?

ECO2.9× per hour
PRO5.8× per hour
AIR5.8× per hour

How often the entire room air passes through the unit per hour at the highest fan speed: airflow divided by room volume.

Turn it.
Look inside.

Drag with your mouse or finger to see the CLAIR PRO from every side. «Inside» makes the housing transparent: the four fans at the top, the two light traps, the five OSRAM UV-C lamps in between and the path of the air from bottom to top.

Drag to rotate

CLAIR PRO

Upkeep that costs next to nothing.

  • 0filters. Nothing to buy, nothing to change, no filter waste.
  • 1×lamp change a year in continuous operation, all lamps at once.
  • 2×cleanings a year: wipe down and vacuum inside.
  • 0.18kWh of electricity per hour with the ECO. No consumables except the lamps.

Frequently asked questions.

Is UV-C dangerous when people are in the room?

No. The UV-C light only acts inside the closed unit. Light traps made of multi-bend louvres let air through but no light out. That is why CLAIR runs in normal operation while people are in the room.

Does it produce ozone?

No. The OSRAM lamps operate at 254 nm and are ozone-free.

Do I have to change filters?

No. CLAIR works without filters. There is nothing that clogs, has to be bought or disposed of as filter waste.

How often are the lamps changed?

Once a year in round-the-clock operation, at the latest after 9,000 operating hours, always all lamps at once. On PRO and AIR the ClairPro app shows the remaining lamp life.

Can the airflow be adjusted?

Yes. PRO and AIR are rated at 600 m³ per hour and have three fan speeds that you select in the ClairPro app. The ECO is rated at 300 m³ per hour and has two speeds on the illuminated button. The lamps never run without airflow.

How loud is CLAIR?

The ECO runs at 34 to 40 dB, PRO and AIR at 34 to 44 dB, depending on the fan speed.

What does it cost to run?

Mainly electricity: the ECO uses 0.18 kWh per hour, the PRO 0.30 kWh and the AIR 0.36 kWh. Plus new lamps once a year in continuous operation. There are no filter costs.

How is CLAIR installed?

ECO and PRO stand on castors and are simply plugged in. The AIR hangs on cables from the ceiling or on the wall.

Has its effectiveness been tested?

Yes. In 2022 an independent test laboratory in Germany measured on CLAIR: 99.4 % fewer active model viruses after one pass and over 85 % fewer germs in the room air after one hour.

Let’s talk about your rooms.

Emailemail@clairproair.com
Phone+41 71 672 35 52
Address

Senza Aqua International GmbH